Same as Model UP7 except cross-bar contacts of PGS material (Platinum, Gold and Silver Alloy) |
||
Long-term stability and reliability in contact resistance | ||
Specifications | Dimensions (mm) | Applications | ||||
Operating Temp | 55`150 i5 stepj |
Overheat Protector for electronic circuit |
||||
Tolerance | }5,}7,}10 | Switching Power Supply | ||||
Differential | 30}15K(Standardj | UPS | ||||
Breaking capacity |
1A 125V AC 6000 cycle(resistive) 0.5A 250V AC 10000 cycle(resistive) |
Inverter Ballast | ||||
Motor Control Inverter | ||||||
Other electronic devices |
Safety Approval* *Contact us for approved conditions in detail. | ||||||
Model |
Agency |
Standard |
Category |
Electrical Ratings |
Max Temp |
File No. |
UP71G UP72G |
UL |
UL873 |
Regulating |
1A/125V AC (resistive)6000cycles |
140 |
E50124 |
c-UL |
CSA C22.2 No.24 |
Appliance Control |
1A/125V AC (resistive)6000cycles |
140 |
E50124 |
|
EN(VDE) |
EN IEC 60730-2-9 |
Thermal Cut-out |
0.5A/250V AC(resistive)10000cycles |
150 |
40023061 |
CQC |
GB14536.10 |
Thermostat (Non-fused bimetal type) |
1A/125V, 0.5A/250V AC |
150 |
CQC04002009091 CQC03002008321 |
|
Mounting method | |||||
In case of sensing heat directly from the heat source, place the thermal protector to touch itfs opposite surface of gUCHIYAh printed surface to the heat source. *In case of sensing convection heat or heat emission, please contact Uchiya. The condition of sensing heat differ case by case. |
||||||