Same as Model UP6 except cross-bar contacts of PGS material (Platinum, Gold and Silver Alloy) |
![]() |
Long-term stability and reliability in contact resistance |
![]() |
|
![]() |
![]() |
|
Operating Temp |
![]() |
Tolerance | ![]() |
Differential | ![]() |
Breaking Capacity |
1A 125V AC 6000 cycle (resistive) 0.5A 250V AC 10000 cycle (resistive) |
![]() |
Overheat Protector for electronic circuit |
Switching Power Supply |
UPS |
Inverter Ballast |
Motor Control Inverter |
Other electronic devices |
![]() |
||||||
Model |
Agency |
Standard |
Category |
Electrical Ratings |
Max Temp |
File No. |
UP61G UP62G |
UL |
UL873 |
Regulating |
1A/125V AC (resistive) 6000 cycles |
140 C |
E50124 |
c-UL |
CSA C22.2 No.24 |
Appliance Control |
1A/125V AC (resistive) 6000 cycles |
140 C |
E50124 |
|
EN(VDE) |
EN IEC 60730-2-9 |
Thermal Cut-out |
0.5A/250V AC (resistive) 10000 cycles |
150 C |
40023061 |
|
CQC |
GB 14536.10 |
Thermostat (Non-fused bimetal type) |
1A/125V, 0.5A/250V AC |
150 C |
CQC04002009091 CQC03002008321 |
![]() |
![]() ![]() |
|
Mounting method | ![]() |
|
In case of sensing heat directly from the heat source, place the thermal protector to touch it’s opposite surface of “UCHIYA” printed surface to the heat source. *In case of sensing convection heat or heat emission, please contact Uchiya. The condition of sensing heat differ case by case. |
||
![]() |
||
![]() |